Industry · Exclusive FRANKONIA distributor
Our products for industry
EuroMC is the exclusive distributor of FRANKONIA in France and the Maghreb. FRANKONIA is a leading company in the field of EMC.
The range
Anechoic chambers and shielded enclosures
Click on a chamber to see its description and technical data and to download its datasheet.
Comparison
Which chamber for which need?
| Model | Use | Frequency range | Distance | External dimensions |
|---|---|---|---|---|
| UCC | R&D pre-compliance, alternative to GTEM cells | 30 MHz – 18 GHz | 1 m | 4.28 × 3.08 × 2.55 m |
| CHC | IEC/EN 61000-4-3 immunity at 3 m, pre-compliance emission | 30 MHz – 18 GHz | 3 m | 7.355 × 3.755 × 3.30 m |
| ACTC | Automotive components DIN/ISO 11452-2, EN 55025 (CISPR 25) | 30 MHz – 18 GHz | 1 m | 6.38 × 5.48 × 3.75 m |
| AVTC | Vehicles CISPR 12/25, ISO 11451-2 / 11452-2 | 26 MHz – 18 GHz (40 GHz option) | 3 m | 11.48 × 9.38 × 6.00 m |
| MIL-CHC | Emission and immunity to MIL-STD 461E | 30 MHz – 18 GHz | 1 m | 4.88 × 4.88 × 3.00 m |
| SAC 3/5 Plus | Compliance at 3 m or 5 m (NSA and SVSWR) | 26 MHz – 18 GHz | 3 m / 5 m | 9.68 × 6.53 × 6.0 m / 12.68 × 7.73 × 6.0 m |
| FAC 3 / FAC 5 | Test site without ground plane (CISPR 16-1-4) | 26 MHz – 18 GHz | 3 m / 5 m | 10.58 × 6.08 × 7.50 m / 12.08 × 8.18 × 7.50 m |
| SAC 10 | Measurements at 3 m and 10 m, quiet zone from 2 to 5 m | 26 MHz – 18 GHz | 3 m and 10 m | from 21.08 × 13.73 × 8.55 m to 23.48 × 16.58 × 9.00 m |

FRANKONIA · UCC
Ultra-compact chamber UCC
Range 30 MHz – 18 GHzDistance 1 mDimensions 4.28 × 3.08 × 2.55 m
The UCC is an alternative to GTEM cells for pre-compliance measurements in research and science. The walls and ceiling of this chamber are completely covered with ferrites. The rear wall, close to the equipment under test, is fitted with hybrid absorbers over an area of 6 m², enabling measurements over a frequency range from 30 MHz to 18 GHz.
Compared with GTEM cells, this chamber offers significant advantages: staff can enter it and install the equipment under test more easily, the test set-up with the power cable corresponding to the peripheral equipment is practical, and larger items can be tested.
The UCC can be used for 1 m pre-compliance radiated emission measurements and immunity tests according to IEC/EN 61000-4-3. It is also ideally suited to pre-compliance measurements of automotive components according to DIN/ISO 11452-2 and EN 55025 (CISPR 25). If required, the UCC can also be used as a standard Faraday cage for conducted immunity tests. Thanks to its small size, it can be installed in laboratories or offices.
Technical data, equipment and options — UCC
Technical data
| Characteristic | Value |
|---|---|
| External dimensions | 4.280 m × 3.080 m × 2.550 m |
| Frequency range | 30 MHz to 18 GHz |
| Measurement distance | 1 m |
| Lining – walls and ceiling | Ferrite type F006 |
| Lining – wall behind the equipment under test | Hybrid absorbers type HF300 over an area of 6 m² |
| Lining – floor | Ferrites over 2 m² between the object under test and the antenna |
| Emission measurements | Pre-compliance measurements |
| Immunity tests | Compliance measurements to IEC/EN 61000-4-3 at a distance of 1 m |
| Vertical field uniformity plane size (IEC/EN 61000-4-3) | 0.5 m × 0.5 m |
| Maximum deviation | -0 dB / +6 dB over all 4 measured points |
Standard equipment
- 1x access door, 0.938 × 1.968 m
- 1x honeycomb vent
- 1 power filter 250 VAC, 2×16 A
- 1 feed-through panel
- Cable feed-throughs: 4x N, 4x BNC and 1x for optical fibre
- Electrical equipment
- Lighting
- Raised floor
- Absorber lining
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Performance verification
- Measuring instrumentation
- Other

FRANKONIA · CHC
Compact hybrid chamber CHC
Range 30 MHz – 18 GHzDistance 3 mDimensions 7.355 × 3.755 × 3.30 m
The CHC is the best solution for immunity tests to IEC/EN 61000-4-3 at 3 m, and offers the best performance for pre-compliance emission tests. Ferrites combined with hybrid absorbers on part of the surfaces allow measurements over a frequency range from 30 MHz to 18 GHz.
This chamber is also available with a ground plane (semi-anechoic) or with absorbers over the whole floor (fully anechoic). For immunity tests, floor absorbers are required between the transmitting antenna and the object under test, which is why they are included in the standard version.
Technical data, equipment and options — CHC
Technical data
| Characteristic | Value |
|---|---|
| External dimensions | 7.355 × 3.755 × 3.300 m (l × L × h) |
| Frequency range | 30 MHz to 18 GHz |
| Measurement distance | 3 m |
| Lining – long walls | Ferrite type F006 + 7.2 m² hybrid absorbers H450 in the centre |
| Lining – wall behind the object under test | Ferrite type F006 + 9.9 m² hybrid absorbers H450 in the centre |
| Lining – wall behind the antenna | Ferrite type F006 (measurements > 1 GHz with horn antennas) |
| Lining – ceiling | Ferrite type F006 + 5.76 m² hybrid absorbers H450 in the centre |
| Floor (SAC) | 7.2 m² hybrid absorbers H450 (movable) |
| Floor (FAC) | Ferrite type F006 + 7.2 m² hybrid absorbers H450 in the centre |
| Emission measurements | Pre-compliance measurements |
| Immunity tests | Compliance to IEC/EN 61000-4-3 at a distance of 3.0 m |
| Vertical field uniformity plane size (IEC/EN 61000-4-3) | 1.5 m × 1.5 m |
| Maximum deviation | -0 dB / +6 dB over 75% of the 16 measured points |
Standard equipment
- 1x access door, 0.938 × 1.968 m
- 1x honeycomb vent
- 1 power filter 250 VAC, 2×16 A
- 1 feed-through panel
- Cable feed-throughs: 4x N, 4x BNC and 1x for optical fibre
- Electrical equipment
- Lighting
- Raised floor
- Absorber lining
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Performance verification
- Measuring instrumentation
- Other

FRANKONIA · ACTC
Anechoic chamber for automotive component testing ACTC
Range 30 MHz – 18 GHzDistance 1 mDimensions 6.38 × 5.48 × 3.75 m
The ACTC has been specially developed for radiation tests of automotive components to DIN/ISO 11452-2 and EN 55025 (CISPR 25), and has been adapted in detail for this purpose. It is lined with ferrites and hybrid absorbers over about half of the chamber. In the standard version, the floor is a raised floor. This chamber is also available with a ground plane or floor absorbers (option).
The standard ACTC is designed for measurements over a frequency range from 30 MHz to 18 GHz. A plug-in contact strip is included in the standard version together with the test table; this strip is installed between the absorbers to ensure the electrical contact of the test table ground plane with the shielded panels.
Technical data, equipment and options — ACTC
Technical data
| Characteristic | Value |
|---|---|
| External dimensions | 6.380 × 5.480 × 3.750 m (l × L × h) |
| Frequency range | 30 MHz to 18 GHz |
| Measurement distance | 1 m |
| Lining – walls and ceiling | Ferrite type F006 |
| Lining – wall behind the equipment under test | Hybrid absorbers type H450 over about half of the chamber |
| Lining – floor | Option |
| Emission measurements | To EN 55025/CISPR 25 (requirements for absorber-lined chambers, absorption performance min. > 6 dB) |
| Immunity tests | To DIN/ISO 11452-2 (reduction of reflections in the test area min. -10 dB) |
Standard equipment
- 1x access door, 1.088 × 1.968 m
- 4x honeycomb vents
- 1 power filter 250 VAC, 2×32 A
- 2 feed-through panels
- Cable feed-throughs: 6x N, 6x BNC and 4x for optical fibre
- Electrical equipment including lighting
- Contact strip and test table
- Raised floor
- Absorber lining
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Ground plane
- Non-combustible hybrid absorbers
- Floor absorbers
- Performance verification
- Other

FRANKONIA · AVTC
Anechoic chamber for vehicle testing AVTC
Range 26 MHz – 18 GHz (40 GHz option)Distance 3 mDimensions 11.48 × 9.38 × 6.00 m
The AVTC is a chamber for radiated emission and immunity tests on vehicles and their components to CISPR 12/25 and ISO 11451-2 / ISO 11452-2. Its standard dimensions allow vehicles up to 5.5 m long to be tested (on a turntable) at a distance of 3 m.
By adding floor absorbers (option), the chamber can be upgraded for emission tests to EN 55022 (CISPR 16-1-4) and immunity tests to IEC 61000-4-3.
Technical data, equipment and options — AVTC
Technical data
| Characteristic | Value |
|---|---|
| External dimensions | 11.480 × 9.380 × 6.000 m (l × L × h) |
| Frequency range | 26 MHz to 18 GHz (40 GHz option) |
| Measurement distance | 3.0 m |
| Lining – walls and ceiling | Hybrid absorbers type H600 |
| Lining – floor | Option |
| Emission measurements | Compliance tests to CISPR 12 / CISPR 25 and EN 55022 (30 MHz to 1 GHz); option (with floor absorbers) to CISPR 16-1-4 from 1 to 18 GHz |
| Immunity tests | Compliance to ISO 11451-2 and ISO 11452-2; option (with floor absorbers) for compliance tests to IEC/EN 61000-4-3 |
Standard equipment
- 1x access door, 0.938 × 1.968 m
- Sliding door, 3.5 × 3.5 m
- 1 power filter 440 VAC, 4×32 A
- 2 feed-through panels
- Electrical equipment
- Lighting
- Absorber lining
- Feed-throughs: 8x N, 8x BNC and 4 optical fibres
- Raised floor
- Ground plane
- Turntable, diameter 5 to 8 m
- Antenna mast 1-4 m
- Controller for antenna mast and turntable
- 10 honeycomb vents
Options
- Additional power filters
- Signal and/or data line filter
- Non-combustible absorbers
- Measuring instrumentation
- Floor absorbers
- Video and/or audio system
- Performance verification

FRANKONIA · MIL-CHC
Anechoic chamber for MIL-STD 461E testing MIL-CHC
Range 30 MHz – 18 GHzDistance 1 mDimensions 4.88 × 4.88 × 3.00 m
The MIL-CHC chamber has been designed to meet the requirements of radiated emission and immunity tests to MIL-STD 461E. The standard dimensions specified below are suitable for a test table up to 3 m wide. Larger dimensions are also available.
The standard version includes the contact strip for the test table as well as the table itself.
Technical data, equipment and options — MIL-CHC
Technical data
| Characteristic | Value |
|---|---|
| External dimensions | 4.880 × 4.880 × 3.000 m (l × L × h) |
| Frequency range | From 30 MHz to 18 GHz |
| Measurement distance | 1.0 m |
| Lining – walls and ceiling | Ferrite type F006 + hybrid absorbers H450 over about half of the chamber |
| Lining – floor | Option |
| Emission measurements | To MIL-STD 461E |
| Immunity tests | To MIL-STD 461E |
| Absorption at normal incidence, 80 MHz – 200 MHz | ≥ 6 dB |
| Absorption at normal incidence, above 200 MHz | ≥ 10 dB |
Standard equipment
- 1x access door, 0.938 × 1.968 m
- 2x honeycomb vents
- 1 power filter 250 VAC, 2×32 A
- 2 feed-through panels
- Cable feed-throughs: 6x N, 6x BNC and 2 optical fibres
- Electrical equipment including lighting
- Contact strip and test table
- Raised floor
- Absorber lining
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Non-combustible absorbers
- Performance verification
- Other

FRANKONIA · SAC 3/5 Plus
Semi-anechoic chamber SAC 3/5 Plus
Range 26 MHz – 18 GHzDistance 3 m / 5 mDimensions 9.68 × 6.53 × 6.0 m / 12.68 × 7.73 × 6.0 m
The SAC 3/5 Plus is a fully compliant semi-anechoic chamber for measurements at 3 or 5 m. Its dome-shaped ceiling and the optimised arrangement of absorbers – combining ferrites and hybrid absorbers – cover a frequency range from 26 MHz to 18 GHz and minimise reflections. Thanks to the reduced size of the hybrid absorbers, this chamber is smaller than chambers built with long pyramids.
The SAC 3/5 Plus guarantees outstanding performance in line with the site validation standard, both in NSA (+3 dB) from 30 MHz to 1 GHz and in SVSWR (4 dB) from 1 to 18 GHz. The standard version includes an antenna mast for a scan height of 1 to 4 m, a turntable and a controller.
Technical data, equipment and options — SAC 3/5 Plus
Technical data
| Characteristic | SAC 3 Plus | SAC 5 Plus |
|---|---|---|
| External dimensions | 9.68 × 6.53 × 6.0 m (l × L × h) | 12.68 × 7.73 × 6.0 m (l × L × h) |
| Frequency range | From 26 MHz to 18 GHz | From 26 MHz to 18 GHz |
| Measurement distance | 3.0 m | 5.0 m |
| Lining – walls and ceiling | Full lining with F006 ferrites and partial lining with H600 and H1000 hybrid absorbers | same |
| Lining – floor | 9 m² of P600 pyramidal absorbers (movable) for immunity tests | same |
| Emission measurements | Compliant with EN 55022 and CISPR 22 Class B (30 MHz – 1 GHz) | same |
| Immunity tests | Compliant with CISPR 16-2-3 (1 to 18 GHz) | same |
| Max. NSA deviation to CISPR 16-1-4 | +4 dB, option +3.5 dB or +3 dB | +4 dB, option +3.5 dB |
| Max. SVSWR deviation to CISPR 16-1-4 | 6 dB, option 5 dB or 4 dB | 6 dB, option 5 dB or 4 dB |
| Test volume size | Diameter 2.0 m / height 2.0 m | Diameter 2.0 m / height 2.0 m |
| Field uniformity area size | 1.5 m × 1.5 m | 1.5 m × 1.5 m |
| Maximum deviation | 0 dB / +6 dB over 75% of the 16 measured points | 0 dB / +6 dB over 75% of the 16 measured points |
Standard equipment
- 1x access door, 1.088 × 1.968 m (SAC 3 Plus)
- 1x access door, 1.538 × 2.118 m
- 4 to 6 honeycomb vents
- 1 power filter 250 VAC, 2×32 A
- 1 power filter 440 V, 50/60 Hz, 4×32 A (SAC 5 Plus)
- 2 feed-through panels
- Cable feed-throughs: 6x N, 6x BNC and 2x for optical fibre
- Electrical equipment
- Lighting
- Ground plane
- Raised floor
- Absorber lining
- Turntable
- Antenna mast
- Controller for antenna mast and turntable
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Performance verification
- Measuring instrumentation
- Non-combustible hybrid absorbers
Special features
- Dome-shaped design (better RF performance), space saving for the ventilation duct
- Savings in shielding and absorber surface area
- 3 versions available depending on NSA and SVSWR performance levels

FRANKONIA · FAC 3 / FAC 5
Fully anechoic chamber FAC 3 / FAC 5
Range 26 MHz – 18 GHzDistance 3 m / 5 mDimensions 10.58 × 6.08 × 7.50 m / 12.08 × 8.18 × 7.50 m
FACs are defined in CISPR 16-1-4 as test sites without a ground plane. Compared with SACs (semi-anechoic chambers), they are lined with absorbers not only on the walls and ceiling but also on the floor. The main advantage of FACs is that no ground reflection can occur: a large antenna scan height is therefore not required, which shortens test times.
However, special arrangements are needed for test preparation (since the floor is also covered with absorbers), particularly for large and heavy objects under test. In general, FACs are larger and represent a bigger investment than SACs, but they have the huge advantage of reducing test times.
Technical data, equipment and options — FAC 3 / FAC 5
Technical data
| Characteristic | FAC 3 | FAC 5 |
|---|---|---|
| External dimensions | 10.58 × 6.08 × 7.50 m (l × L × h) | 12.08 × 8.18 × 7.50 m (l × L × h) |
| Frequency range | From 26 MHz to 18 GHz | From 26 MHz to 18 GHz |
| Measurement distance | 3.0 m | 5.0 m |
| Absorbers on walls and ceiling | Full lining with F006 ferrites and partial lining with H600 and H1000 hybrid absorbers | same |
| Emission tests | Compliant with CISPR 16-2-3 | same |
| Max. NSA deviation to CISPR 16-1-4 | +4 dB | +4 dB, option +3.5 dB |
| Max. SVSWR deviation to CISPR 16-1-4 | 6 dB | 6 dB |
| Test volume size | Diameter 1.2 m / height 1.5 m | Diameter 2.0 m / height 2.0 m |
| Immunity tests | Compliant with IEC/EN 61000-4-3 | same |
| Field uniformity area size | 1.5 m × 1.5 m | 1.5 m × 1.5 m |
| Maximum deviation | -0 dB / +6 dB over 75% of the 16 measured points | same |
Standard equipment
- 1x access door, 0.938 × 1.968 m
- 6 honeycomb vents
- 1 power filter 440 VAC, 4×32 A
- 2 feed-through panels
- Electrical equipment
- Lighting
- Wooden floor
- Wooden table
- Absorbers
- Turntable
- Antenna mast
- Controller for antenna mast and turntable
- Raised floor for antenna mast and turntable
- Cable feed-throughs: 6x N, 4x BNC and 4x for optical fibres
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Performance verification
- Instrumentation
- Non-combustible hybrid absorbers

FRANKONIA · SAC 10
10 m anechoic chamber SAC 10
Range 26 MHz – 18 GHzDistance 3 m and 10 mDimensions from 21.08 × 13.73 × 8.55 m to 23.48 × 16.58 × 9.00 m
SAC 10 chambers are designed and built almost exclusively to our customers’ requirements. However, in terms of dimensions and performance, we have defined 4 standards with a quiet zone from 2 to 5 m in diameter.
The design of such a chamber must start as early as possible, i.e. together with the planning of the building itself, so that the interfaces are defined in time and later modifications are avoided. By interfaces we mean all kinds of connections, floor recesses for turntables / roller test benches or for sliding doors, and the fixing of the chamber to the building. Further interfaces such as emergency control and alarm systems (fire alarm and sprinklers) must also be taken into account. Such systems are normally not required when the chamber is fitted with class A2 non-combustible pyramidal absorbers (film absorbers).
Technical data, equipment and options — SAC 10
Technical data
| Characteristic | SAC-10-2 | SAC-10-3 | SAC-10-4 | SAC-10-5 |
|---|---|---|---|---|
| Quiet zone diameter | 2.0 m | 3.0 m | 4.0 m | 5.0 m |
| External shielding dimensions (W × L × H) | 21.08 × 13.73 × 8.55 m | 21.68 × 13.73 × 8.55 m | 22.58 × 15.98 × 9.00 m | 23.48 × 16.58 × 9.00 m |
| Characteristic | All versions |
|---|---|
| Frequency range | From 26 MHz to 18 GHz |
| Measurement distance | 3 m and 10 m |
| Walls and ceiling | Long P2200 and P2400 pyramidal absorbers |
| Floor | Movable absorbers for immunity tests to IEC/EN 61000-4-3 and for emission tests > 1 GHz (SVSWR) |
| Emission tests | Compliant with CISPR 16-2-3 and CISPR 22 |
| Max. normalised site attenuation deviation to CISPR 16-1-4 | +3.5 dB |
| Max. SVSWR deviation to CISPR 16-1-4 | 6 dB |
| Immunity tests | Compliant with IEC/EN 61000-4-3 |
| Maximum deviation | -0 dB / +6 dB over 75% of the 16 measured points |
| Field uniformity area size | 1.5 m × 1.5 m |
Standard equipment
- 1x single-leaf sliding door
- 12-16 honeycomb vents
- 1 power filter 250 VAC, 2×16 A
- 1 power filter 440 VAC, 4×16 A
- Electrical equipment
- Lighting
- Wooden floor
- Wooden table
- Absorbers
- Turntable
- Antenna mast
- Controller for antenna mast and turntable
- Raised floor for antenna mast and turntable
- Cable feed-throughs: 6x N, 4x BNC and 4x for optical fibres
Options
- Three-phase power filter
- Signal and/or data line filter
- Fan
- Antenna support
- Video and/or audio system
- Performance verification
- Instrumentation
- Non-combustible hybrid absorbers
An anechoic chamber or shielded enclosure project?
Standard or custom-built, we study your needs and propose the right solution.