Menu Close
Anechoic chamber for automotive EMC testing

Industry · Exclusive FRANKONIA distributor

Our products for industry

EuroMC is the exclusive distributor of FRANKONIA in France and the Maghreb. FRANKONIA is a leading company in the field of EMC.

The range

Anechoic chambers and shielded enclosures

Click on a chamber to see its description and technical data and to download its datasheet.

Ultra-compact chamber UCC

UCC

Ultra-compact chamber

Pre-compliance · 1 m

Compact hybrid chamber CHC

CHC

Compact hybrid chamber

Immunity at 3 m

Anechoic chamber for vehicle testing AVTC

AVTC

Anechoic chamber for vehicle testing

Vehicles up to 5.5 m

Anechoic chamber for MIL-STD 461E testing MIL-CHC

MIL-CHC

Anechoic chamber for MIL-STD 461E testing

Military tests MIL-STD 461E

Semi-anechoic chamber SAC 3/5 Plus

SAC 3/5 Plus

Semi-anechoic chamber

Compliance at 3 m or 5 m

Fully anechoic chamber FAC 3 / FAC 5

FAC 3 / FAC 5

Fully anechoic chamber

No ground plane · 3 m / 5 m

10 m anechoic chamber SAC 10

SAC 10

10 m anechoic chamber

10 m measurements · custom-built

Comparison

Which chamber for which need?

ModelUseFrequency rangeDistanceExternal dimensions
UCCR&D pre-compliance, alternative to GTEM cells30 MHz – 18 GHz1 m4.28 × 3.08 × 2.55 m
CHCIEC/EN 61000-4-3 immunity at 3 m, pre-compliance emission30 MHz – 18 GHz3 m7.355 × 3.755 × 3.30 m
ACTCAutomotive components DIN/ISO 11452-2, EN 55025 (CISPR 25)30 MHz – 18 GHz1 m6.38 × 5.48 × 3.75 m
AVTCVehicles CISPR 12/25, ISO 11451-2 / 11452-226 MHz – 18 GHz (40 GHz option)3 m11.48 × 9.38 × 6.00 m
MIL-CHCEmission and immunity to MIL-STD 461E30 MHz – 18 GHz1 m4.88 × 4.88 × 3.00 m
SAC 3/5 PlusCompliance at 3 m or 5 m (NSA and SVSWR)26 MHz – 18 GHz3 m / 5 m9.68 × 6.53 × 6.0 m / 12.68 × 7.73 × 6.0 m
FAC 3 / FAC 5Test site without ground plane (CISPR 16-1-4)26 MHz – 18 GHz3 m / 5 m10.58 × 6.08 × 7.50 m / 12.08 × 8.18 × 7.50 m
SAC 10Measurements at 3 m and 10 m, quiet zone from 2 to 5 m26 MHz – 18 GHz3 m and 10 mfrom 21.08 × 13.73 × 8.55 m to 23.48 × 16.58 × 9.00 m
Ultra-compact chamber UCC

FRANKONIA · UCC

Ultra-compact chamber UCC

Range 30 MHz – 18 GHzDistance 1 mDimensions 4.28 × 3.08 × 2.55 m

The UCC is an alternative to GTEM cells for pre-compliance measurements in research and science. The walls and ceiling of this chamber are completely covered with ferrites. The rear wall, close to the equipment under test, is fitted with hybrid absorbers over an area of 6 m², enabling measurements over a frequency range from 30 MHz to 18 GHz.

Compared with GTEM cells, this chamber offers significant advantages: staff can enter it and install the equipment under test more easily, the test set-up with the power cable corresponding to the peripheral equipment is practical, and larger items can be tested.

The UCC can be used for 1 m pre-compliance radiated emission measurements and immunity tests according to IEC/EN 61000-4-3. It is also ideally suited to pre-compliance measurements of automotive components according to DIN/ISO 11452-2 and EN 55025 (CISPR 25). If required, the UCC can also be used as a standard Faraday cage for conducted immunity tests. Thanks to its small size, it can be installed in laboratories or offices.

Technical data, equipment and options — UCC

Technical data

CharacteristicValue
External dimensions4.280 m × 3.080 m × 2.550 m
Frequency range30 MHz to 18 GHz
Measurement distance1 m
Lining – walls and ceilingFerrite type F006
Lining – wall behind the equipment under testHybrid absorbers type HF300 over an area of 6 m²
Lining – floorFerrites over 2 m² between the object under test and the antenna
Emission measurementsPre-compliance measurements
Immunity testsCompliance measurements to IEC/EN 61000-4-3 at a distance of 1 m
Vertical field uniformity plane size (IEC/EN 61000-4-3)0.5 m × 0.5 m
Maximum deviation-0 dB / +6 dB over all 4 measured points

Standard equipment

  • 1x access door, 0.938 × 1.968 m
  • 1x honeycomb vent
  • 1 power filter 250 VAC, 2×16 A
  • 1 feed-through panel
  • Cable feed-throughs: 4x N, 4x BNC and 1x for optical fibre
  • Electrical equipment
  • Lighting
  • Raised floor
  • Absorber lining

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Performance verification
  • Measuring instrumentation
  • Other
Compact hybrid chamber CHC

FRANKONIA · CHC

Compact hybrid chamber CHC

Range 30 MHz – 18 GHzDistance 3 mDimensions 7.355 × 3.755 × 3.30 m

The CHC is the best solution for immunity tests to IEC/EN 61000-4-3 at 3 m, and offers the best performance for pre-compliance emission tests. Ferrites combined with hybrid absorbers on part of the surfaces allow measurements over a frequency range from 30 MHz to 18 GHz.

This chamber is also available with a ground plane (semi-anechoic) or with absorbers over the whole floor (fully anechoic). For immunity tests, floor absorbers are required between the transmitting antenna and the object under test, which is why they are included in the standard version.

Technical data, equipment and options — CHC

Technical data

CharacteristicValue
External dimensions7.355 × 3.755 × 3.300 m (l × L × h)
Frequency range30 MHz to 18 GHz
Measurement distance3 m
Lining – long wallsFerrite type F006 + 7.2 m² hybrid absorbers H450 in the centre
Lining – wall behind the object under testFerrite type F006 + 9.9 m² hybrid absorbers H450 in the centre
Lining – wall behind the antennaFerrite type F006 (measurements > 1 GHz with horn antennas)
Lining – ceilingFerrite type F006 + 5.76 m² hybrid absorbers H450 in the centre
Floor (SAC)7.2 m² hybrid absorbers H450 (movable)
Floor (FAC)Ferrite type F006 + 7.2 m² hybrid absorbers H450 in the centre
Emission measurementsPre-compliance measurements
Immunity testsCompliance to IEC/EN 61000-4-3 at a distance of 3.0 m
Vertical field uniformity plane size (IEC/EN 61000-4-3)1.5 m × 1.5 m
Maximum deviation-0 dB / +6 dB over 75% of the 16 measured points

Standard equipment

  • 1x access door, 0.938 × 1.968 m
  • 1x honeycomb vent
  • 1 power filter 250 VAC, 2×16 A
  • 1 feed-through panel
  • Cable feed-throughs: 4x N, 4x BNC and 1x for optical fibre
  • Electrical equipment
  • Lighting
  • Raised floor
  • Absorber lining

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Performance verification
  • Measuring instrumentation
  • Other
Anechoic chamber for automotive component testing ACTC

FRANKONIA · ACTC

Anechoic chamber for automotive component testing ACTC

Range 30 MHz – 18 GHzDistance 1 mDimensions 6.38 × 5.48 × 3.75 m

The ACTC has been specially developed for radiation tests of automotive components to DIN/ISO 11452-2 and EN 55025 (CISPR 25), and has been adapted in detail for this purpose. It is lined with ferrites and hybrid absorbers over about half of the chamber. In the standard version, the floor is a raised floor. This chamber is also available with a ground plane or floor absorbers (option).

The standard ACTC is designed for measurements over a frequency range from 30 MHz to 18 GHz. A plug-in contact strip is included in the standard version together with the test table; this strip is installed between the absorbers to ensure the electrical contact of the test table ground plane with the shielded panels.

Technical data, equipment and options — ACTC

Technical data

CharacteristicValue
External dimensions6.380 × 5.480 × 3.750 m (l × L × h)
Frequency range30 MHz to 18 GHz
Measurement distance1 m
Lining – walls and ceilingFerrite type F006
Lining – wall behind the equipment under testHybrid absorbers type H450 over about half of the chamber
Lining – floorOption
Emission measurementsTo EN 55025/CISPR 25 (requirements for absorber-lined chambers, absorption performance min. > 6 dB)
Immunity testsTo DIN/ISO 11452-2 (reduction of reflections in the test area min. -10 dB)

Standard equipment

  • 1x access door, 1.088 × 1.968 m
  • 4x honeycomb vents
  • 1 power filter 250 VAC, 2×32 A
  • 2 feed-through panels
  • Cable feed-throughs: 6x N, 6x BNC and 4x for optical fibre
  • Electrical equipment including lighting
  • Contact strip and test table
  • Raised floor
  • Absorber lining

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Ground plane
  • Non-combustible hybrid absorbers
  • Floor absorbers
  • Performance verification
  • Other
Anechoic chamber for vehicle testing AVTC

FRANKONIA · AVTC

Anechoic chamber for vehicle testing AVTC

Range 26 MHz – 18 GHz (40 GHz option)Distance 3 mDimensions 11.48 × 9.38 × 6.00 m

The AVTC is a chamber for radiated emission and immunity tests on vehicles and their components to CISPR 12/25 and ISO 11451-2 / ISO 11452-2. Its standard dimensions allow vehicles up to 5.5 m long to be tested (on a turntable) at a distance of 3 m.

By adding floor absorbers (option), the chamber can be upgraded for emission tests to EN 55022 (CISPR 16-1-4) and immunity tests to IEC 61000-4-3.

Technical data, equipment and options — AVTC

Technical data

CharacteristicValue
External dimensions11.480 × 9.380 × 6.000 m (l × L × h)
Frequency range26 MHz to 18 GHz (40 GHz option)
Measurement distance3.0 m
Lining – walls and ceilingHybrid absorbers type H600
Lining – floorOption
Emission measurementsCompliance tests to CISPR 12 / CISPR 25 and EN 55022 (30 MHz to 1 GHz); option (with floor absorbers) to CISPR 16-1-4 from 1 to 18 GHz
Immunity testsCompliance to ISO 11451-2 and ISO 11452-2; option (with floor absorbers) for compliance tests to IEC/EN 61000-4-3

Standard equipment

  • 1x access door, 0.938 × 1.968 m
  • Sliding door, 3.5 × 3.5 m
  • 1 power filter 440 VAC, 4×32 A
  • 2 feed-through panels
  • Electrical equipment
  • Lighting
  • Absorber lining
  • Feed-throughs: 8x N, 8x BNC and 4 optical fibres
  • Raised floor
  • Ground plane
  • Turntable, diameter 5 to 8 m
  • Antenna mast 1-4 m
  • Controller for antenna mast and turntable
  • 10 honeycomb vents

Options

  • Additional power filters
  • Signal and/or data line filter
  • Non-combustible absorbers
  • Measuring instrumentation
  • Floor absorbers
  • Video and/or audio system
  • Performance verification
Anechoic chamber for MIL-STD 461E testing MIL-CHC

FRANKONIA · MIL-CHC

Anechoic chamber for MIL-STD 461E testing MIL-CHC

Range 30 MHz – 18 GHzDistance 1 mDimensions 4.88 × 4.88 × 3.00 m

The MIL-CHC chamber has been designed to meet the requirements of radiated emission and immunity tests to MIL-STD 461E. The standard dimensions specified below are suitable for a test table up to 3 m wide. Larger dimensions are also available.

The standard version includes the contact strip for the test table as well as the table itself.

Technical data, equipment and options — MIL-CHC

Technical data

CharacteristicValue
External dimensions4.880 × 4.880 × 3.000 m (l × L × h)
Frequency rangeFrom 30 MHz to 18 GHz
Measurement distance1.0 m
Lining – walls and ceilingFerrite type F006 + hybrid absorbers H450 over about half of the chamber
Lining – floorOption
Emission measurementsTo MIL-STD 461E
Immunity testsTo MIL-STD 461E
Absorption at normal incidence, 80 MHz – 200 MHz≥ 6 dB
Absorption at normal incidence, above 200 MHz≥ 10 dB

Standard equipment

  • 1x access door, 0.938 × 1.968 m
  • 2x honeycomb vents
  • 1 power filter 250 VAC, 2×32 A
  • 2 feed-through panels
  • Cable feed-throughs: 6x N, 6x BNC and 2 optical fibres
  • Electrical equipment including lighting
  • Contact strip and test table
  • Raised floor
  • Absorber lining

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Non-combustible absorbers
  • Performance verification
  • Other
Semi-anechoic chamber SAC 3/5 Plus

FRANKONIA · SAC 3/5 Plus

Semi-anechoic chamber SAC 3/5 Plus

Range 26 MHz – 18 GHzDistance 3 m / 5 mDimensions 9.68 × 6.53 × 6.0 m / 12.68 × 7.73 × 6.0 m

The SAC 3/5 Plus is a fully compliant semi-anechoic chamber for measurements at 3 or 5 m. Its dome-shaped ceiling and the optimised arrangement of absorbers – combining ferrites and hybrid absorbers – cover a frequency range from 26 MHz to 18 GHz and minimise reflections. Thanks to the reduced size of the hybrid absorbers, this chamber is smaller than chambers built with long pyramids.

The SAC 3/5 Plus guarantees outstanding performance in line with the site validation standard, both in NSA (+3 dB) from 30 MHz to 1 GHz and in SVSWR (4 dB) from 1 to 18 GHz. The standard version includes an antenna mast for a scan height of 1 to 4 m, a turntable and a controller.

Technical data, equipment and options — SAC 3/5 Plus

Technical data

CharacteristicSAC 3 PlusSAC 5 Plus
External dimensions9.68 × 6.53 × 6.0 m (l × L × h)12.68 × 7.73 × 6.0 m (l × L × h)
Frequency rangeFrom 26 MHz to 18 GHzFrom 26 MHz to 18 GHz
Measurement distance3.0 m5.0 m
Lining – walls and ceilingFull lining with F006 ferrites and partial lining with H600 and H1000 hybrid absorberssame
Lining – floor9 m² of P600 pyramidal absorbers (movable) for immunity testssame
Emission measurementsCompliant with EN 55022 and CISPR 22 Class B (30 MHz – 1 GHz)same
Immunity testsCompliant with CISPR 16-2-3 (1 to 18 GHz)same
Max. NSA deviation to CISPR 16-1-4+4 dB, option +3.5 dB or +3 dB+4 dB, option +3.5 dB
Max. SVSWR deviation to CISPR 16-1-46 dB, option 5 dB or 4 dB6 dB, option 5 dB or 4 dB
Test volume sizeDiameter 2.0 m / height 2.0 mDiameter 2.0 m / height 2.0 m
Field uniformity area size1.5 m × 1.5 m1.5 m × 1.5 m
Maximum deviation0 dB / +6 dB over 75% of the 16 measured points0 dB / +6 dB over 75% of the 16 measured points

Standard equipment

  • 1x access door, 1.088 × 1.968 m (SAC 3 Plus)
  • 1x access door, 1.538 × 2.118 m
  • 4 to 6 honeycomb vents
  • 1 power filter 250 VAC, 2×32 A
  • 1 power filter 440 V, 50/60 Hz, 4×32 A (SAC 5 Plus)
  • 2 feed-through panels
  • Cable feed-throughs: 6x N, 6x BNC and 2x for optical fibre
  • Electrical equipment
  • Lighting
  • Ground plane
  • Raised floor
  • Absorber lining
  • Turntable
  • Antenna mast
  • Controller for antenna mast and turntable

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Performance verification
  • Measuring instrumentation
  • Non-combustible hybrid absorbers

Special features

  • Dome-shaped design (better RF performance), space saving for the ventilation duct
  • Savings in shielding and absorber surface area
  • 3 versions available depending on NSA and SVSWR performance levels
Fully anechoic chamber FAC 3 / FAC 5

FRANKONIA · FAC 3 / FAC 5

Fully anechoic chamber FAC 3 / FAC 5

Range 26 MHz – 18 GHzDistance 3 m / 5 mDimensions 10.58 × 6.08 × 7.50 m / 12.08 × 8.18 × 7.50 m

FACs are defined in CISPR 16-1-4 as test sites without a ground plane. Compared with SACs (semi-anechoic chambers), they are lined with absorbers not only on the walls and ceiling but also on the floor. The main advantage of FACs is that no ground reflection can occur: a large antenna scan height is therefore not required, which shortens test times.

However, special arrangements are needed for test preparation (since the floor is also covered with absorbers), particularly for large and heavy objects under test. In general, FACs are larger and represent a bigger investment than SACs, but they have the huge advantage of reducing test times.

Technical data, equipment and options — FAC 3 / FAC 5

Technical data

CharacteristicFAC 3FAC 5
External dimensions10.58 × 6.08 × 7.50 m (l × L × h)12.08 × 8.18 × 7.50 m (l × L × h)
Frequency rangeFrom 26 MHz to 18 GHzFrom 26 MHz to 18 GHz
Measurement distance3.0 m5.0 m
Absorbers on walls and ceilingFull lining with F006 ferrites and partial lining with H600 and H1000 hybrid absorberssame
Emission testsCompliant with CISPR 16-2-3same
Max. NSA deviation to CISPR 16-1-4+4 dB+4 dB, option +3.5 dB
Max. SVSWR deviation to CISPR 16-1-46 dB6 dB
Test volume sizeDiameter 1.2 m / height 1.5 mDiameter 2.0 m / height 2.0 m
Immunity testsCompliant with IEC/EN 61000-4-3same
Field uniformity area size1.5 m × 1.5 m1.5 m × 1.5 m
Maximum deviation-0 dB / +6 dB over 75% of the 16 measured pointssame

Standard equipment

  • 1x access door, 0.938 × 1.968 m
  • 6 honeycomb vents
  • 1 power filter 440 VAC, 4×32 A
  • 2 feed-through panels
  • Electrical equipment
  • Lighting
  • Wooden floor
  • Wooden table
  • Absorbers
  • Turntable
  • Antenna mast
  • Controller for antenna mast and turntable
  • Raised floor for antenna mast and turntable
  • Cable feed-throughs: 6x N, 4x BNC and 4x for optical fibres

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Performance verification
  • Instrumentation
  • Non-combustible hybrid absorbers
10 m anechoic chamber SAC 10

FRANKONIA · SAC 10

10 m anechoic chamber SAC 10

Range 26 MHz – 18 GHzDistance 3 m and 10 mDimensions from 21.08 × 13.73 × 8.55 m to 23.48 × 16.58 × 9.00 m

SAC 10 chambers are designed and built almost exclusively to our customers’ requirements. However, in terms of dimensions and performance, we have defined 4 standards with a quiet zone from 2 to 5 m in diameter.

The design of such a chamber must start as early as possible, i.e. together with the planning of the building itself, so that the interfaces are defined in time and later modifications are avoided. By interfaces we mean all kinds of connections, floor recesses for turntables / roller test benches or for sliding doors, and the fixing of the chamber to the building. Further interfaces such as emergency control and alarm systems (fire alarm and sprinklers) must also be taken into account. Such systems are normally not required when the chamber is fitted with class A2 non-combustible pyramidal absorbers (film absorbers).

Technical data, equipment and options — SAC 10

Technical data

CharacteristicSAC-10-2SAC-10-3SAC-10-4SAC-10-5
Quiet zone diameter2.0 m3.0 m4.0 m5.0 m
External shielding dimensions (W × L × H)21.08 × 13.73 × 8.55 m21.68 × 13.73 × 8.55 m22.58 × 15.98 × 9.00 m23.48 × 16.58 × 9.00 m
CharacteristicAll versions
Frequency rangeFrom 26 MHz to 18 GHz
Measurement distance3 m and 10 m
Walls and ceilingLong P2200 and P2400 pyramidal absorbers
FloorMovable absorbers for immunity tests to IEC/EN 61000-4-3 and for emission tests > 1 GHz (SVSWR)
Emission testsCompliant with CISPR 16-2-3 and CISPR 22
Max. normalised site attenuation deviation to CISPR 16-1-4+3.5 dB
Max. SVSWR deviation to CISPR 16-1-46 dB
Immunity testsCompliant with IEC/EN 61000-4-3
Maximum deviation-0 dB / +6 dB over 75% of the 16 measured points
Field uniformity area size1.5 m × 1.5 m

Standard equipment

  • 1x single-leaf sliding door
  • 12-16 honeycomb vents
  • 1 power filter 250 VAC, 2×16 A
  • 1 power filter 440 VAC, 4×16 A
  • Electrical equipment
  • Lighting
  • Wooden floor
  • Wooden table
  • Absorbers
  • Turntable
  • Antenna mast
  • Controller for antenna mast and turntable
  • Raised floor for antenna mast and turntable
  • Cable feed-throughs: 6x N, 4x BNC and 4x for optical fibres

Options

  • Three-phase power filter
  • Signal and/or data line filter
  • Fan
  • Antenna support
  • Video and/or audio system
  • Performance verification
  • Instrumentation
  • Non-combustible hybrid absorbers

An anechoic chamber or shielded enclosure project?

Standard or custom-built, we study your needs and propose the right solution.