OUR PRODUCT CATALOG
LAST NEWS
- CISPR 16-1-4, NSA and SVSWR – No compromise | 04/12/09 With the modification of the CISPR 16-1-4 Standard (Validation of chambers from 1 to 18 GHz), Frankonia GmbH decided to develop in 2007 a new chamber concept with excellent performances: SAC3+™.
Shielded cabinet
Our range of small chambers is including also the supply of shielded cabinets.
Suitable for testing on small devices, later modifications can be also realized (ferrite tiles, absorbers). They are ruggedized for working on site; they require little space and allow a very easy transportation.
Shielding efficiency
- High attenuation according to MIL-STD 285.
Magnetic field
- 10 kHz 60dB / 100 Khz 90dB
Electrical field
- 300kHz 110dB / 1MHz 115dB / 30MHz 115dB / 1GHz 100dB
Electric installation
-
DC - AC, single-phase or tri-phase
Our technical team will install all types of power in order to guarantee the compliance with attenuation requirements and protection norms as specified.
Accessories
- Due to our experience, we are able to offer adapted accessories to your measurement needs: honeycombs, filters, fans, standard or specific feed-through, RF-absorbers, optic fibres, data signals like RS232, USB, and Ethernet